The Plot Component Results buttons provide shortcuts for the most commonly used plotting options. By activating any of these options, the corresponding results data will be displayed for every component on the active model item.
Important: To plot the data listed below, the component must have results.
Plot No Data
Deactivates all plotting options and displays the FEM with no HyperSizer-computed or imported data.
Plot Minimum Margin of Safety
Displays the minimum margin of safety for each component in the active model item. The margin of safety displayed is the minimum from any active failure mode and load case.
Plot Optimum Beam/Panel Concept
Displays the HyperSizer-computed optimum panel/beam concept for each component in the active model item.
Plot Optimum Unit Weight
Displays the optimum unit weight for each component in the active model item. Units = (lb/ft^2 or kg/m^2)
Plot Controlling Failure Analysis
Displays the controlling failure analysis for each component in the active model item. This failure analysis corresponds to the minimum margin of safety.
Plot Controlling Load Case